Site emissions baseline by source
Every credible transition project starts from a number, and most plants cannot say how many tonnes of CO2 equivalent come from fired heaters, gas turbines, flares, vents, process CO2 and purchased power. Building a source by source baseline for one full year, with the method and data quality noted for each line, gives every later study a fixed reference and stops two teams claiming the same tonnes.
First tasks
- List every fired unit, flare, vent and process CO2 stream on the plot plan
- Request twelve months of fuel gas and flare meter data from the historian
- Record the emission factor and reference used for each source
- Total the baseline by source and send it to the area lead for sign-off